Trade4asia Electrical Calibration Standards TD1470 Single and Double Arm Bridge Calibration Device

TD1470 Single and Double Arm Bridge Calibration Device

TD1470 Single and Double Arm Bridge Calibration Device

TD1470 Single and Double Arm Bridge Calibration Device

Electrical Calibration Standards

The TD1470 is a high-precision DC resistance simulator designed for calibration and verification of measurement instruments requiring wide-range resistance simulation. With its advanced resistance synthesis technology, the TD1470 provides precise, stable, and repeatable outputs across a broad resistance range—from low micro-ohm levels to 100 Ω.

This instrument is suitable for applications such as calibration of single-arm and double-arm bridges, high-accuracy DC resistance meters, and digital micro-ohmmeters. It delivers excellent measurement uncertainty performance along with fine resolution adjustment, making it an ideal standard for metrology laboratories and calibration institutions.

Range Fineness Adjustment 24h Uncertainty (ppm*RD + μΩ) 90 Days Uncertainty (ppm*RD + μΩ) 1 Year Uncertainty (ppm*RD + μΩ) Input Current
1 mΩ 10 nΩ 50 + 0.5 75 + 0.5 100 + 0.5 1 A ~ 10 A
10 mΩ 100 nΩ 50 + 1 75 + 1 100 + 1 0.5 A ~ 5 A
100 mΩ 1 μΩ 50 + 3 75 + 3 100 + 3 0.3 A ~ 5 A
1 Ω 10 μΩ 50 + 15 75 + 15 100 + 15 0.05 A ~ 5 A
10 Ω 100 μΩ 50 + 150 75 + 150 100 + 150 10 mA ~ 300 mA
100 Ω 1 mΩ 50 + 1500 75 + 1500 100 + 1500 1 mA ~ 30 mA

General Specifications

  • Power Supply: AC (220 ± 22)V, (50 ± 2)Hz
  • Warm-Up Time: ≥1 hour (restart warm-up ≥2× shutdown duration)
  • Max Power Consumption: 150 VA
  • Operating Temperature: 18°C ~ 28°C
  • Storage Temperature: -10°C ~ 50°C
  • Operating Humidity: 20% ~ 80% R.H (non-condensing)
  • Storage Humidity: < 85% R.H (non-condensing)
  • Altitude: < 3000 m
  • Weight: Approx. 10 kg
  • Interfaces: RS-232, USB, LAN/IP
  • Dimensions: 400 mm (W) × 265 mm (D) × 190 mm (H)

Key Features

  • Wide adjustable DC resistance simulation from 1 mΩ to 100 Ω.
  • High resolution adjustment enabling ultra-fine control of micro-ohm resistance.
  • Excellent long-term stability with uncertainty as low as 50 ppm depending on range.
  • Designed for calibration of bridges, micro-ohmmeters, and precision resistance meters.
  • Multiple communication interfaces including USB, RS-232, and LAN (IP).
  • Built-in thermal control and protection ensures safe and stable measurement under high currents.
  • Suitable for laboratory-grade metrology and national standard verification systems.
ONsys Technologies OPC Pvt Ltd
Ajay Singh Kushwah ✔ Verified
Maharashtra, Thane West
GST
6 Months Ragular

Ask Price

Price: As per Client
Unit: 0
Type: Products

Suggested Similar TD1470 Single and Double Arm Bridge Calibration Device

Send Inquiry for TD1470 Single and Double Arm Bridge Calibration Device
Inquiry Now

Suggested Similar Category

TD1470 Single and Double Arm Bridge Calibration Device is available in the following areas.